Agilent Technologies E4400-90333 Portable Generator User Manual


 
34 ErrorMessages
-299 to -200: Execution Errors ESG Family Signal Generators
Settings conflict; The current data rate is not valid for this
radio configuration. Data rate changed to the default rate.
The new radio configuration does not support the current data rate. The
data rate changes to the default rate for the new radio configuration,
which is 1× for F-FCH and 2× for F-SCH.
Settings conflict; Current file length does not have an
integer number of symbols. User file size must have symbol
boundary in order to transmit the file.
A user-defined file must end with a symbol. If it does not, transmission is
aborted.
Settings conflict; The current paging indicator (PI) is not
valid for 2400 bps data rate. The PI has been changed to 0,
the default.
QPCH channel with a data rate of 2400 bps only supports up to 191 paging
indicators. The PI has been set to 0 (default value) to remain valid for this
data rate.
Settings conflict; The current RC or data rate does not
support turbo coding. Turbo Coding has been turned off.
Either specification or hardware does not support turbo coding for this
data rate. Turbo coding is now turned off. If you wish to use turbo coding,
select a valid data rate and then turn turbo coding on. For F-SCH
channels, data both rates below 14.4 kbps, and the highest data rates for
each RC are not valid for turbo coding.
Settings conflict; Clipping not allowed for CDMA2000 reverse
radio configs 1 and 2. Clipping set to 100%.
The clipping function is not available for the cdma2000 reverse link radio
configs 1 and 2. The value is automatically reset to 100% (no clipping).
Settings conflict; Continuous protocol timeslots cannot be
turned off.
A continuous protocol timeslot is switched off while in TETRA mode. When
a continuous protocol has been selected for a timeslot in TETRA mode, all
of the timeslots must be switched on.