Markers Field
The Markers field is used to access the markers selection menu. When the
Markers field is selected, a marker selection menu appears with the marker
choices available under the present analyzer configuration.
State Analyzer Markers
In a state analyzer with time and state count turned off in the Trigger menu,
only Pattern markers are available. With time count turned on, choices of
Pattern, Time, and Statistics markers become available.
With states count turned on, Pattern and State markers are available.
Timing Analyzer Markers
In a timing analyzer you have marker choices of Pattern, Time, or Statistics.
Off
The Off selection turns marker operations off. If a Stop measurement was
previously specified and the Stop measurement criteria are met, the
measurement will stop even though the markers are off.
Markers Field
Markers field
The Waveform Menu
Markers Field