PSC PT Program Generator Portable Generator User Manual


 
Example Frames
146 PT Program Generator (PPG) v5.0
Figure 119. The Input: TO FILE Dialog
To download a file to a portable, set options for the Input node as follows:
Verify: DNLD Checks to see if <F3> was pressed and, if it was, continues to the Dis-
play
node. If <F3> was not pressed, the program loops back to the
Input node and waits for further input.
Display: WAIT Displays Downloading, Please Wait on the portable’s screen.
Input: TO FILE Starts downloading the file. Options in its dialog box are set as shown in
Figure 119 on page 146
.
Display: DONE If downloading is successful,
Display: DONE displays DOWNLOAD
DONE; <F3>= MORE; <F4>=QUIT
on the portable’s screen.
Display:
TIMEOUT
If downloading is unsuccessful,
Display: TIMEOUT displays TIME-
OUT EXCEEDED; <F3>=TRY AGAIN; <F4>=QUIT
on the por-
table’s screen.
Input: FKEY Both these
Display nodes loop back to the Input: FKEY node, which
accepts the user’s function key input.
Serial Selected for the
Input From option.
Time Out Selected for the Input From option. Should Link to a Display node
that prompts the user to try again.
Destination
Set to the desired file. Choose to replace existing data or place new
data at the beginning or end of the file or at a given record number.
Echo to Display Enabled so that the user can see the file going into the portable unit.
2342.book Page 146 Thursday, July 22, 2004 8:35 AM