6 Line, Tunnel, Terminal, and Host Settings
XPort Pro™ User Guide 35
Line -
Configuration
Page Settings
Description
Protocol
Select the protocol from the drop-down menu. The default is
Tunnel.
Baud Rate
Select the baud rate from the drop-down menu. The default
is 9600.
Parity
Select the parity from the drop-down menu. The default is
None.
Data Bits
Select the number of data bits from the drop-down menu.
The default is 8.
Stop Bits
Select the number of stop bits from the drop-down menu.
The default is 1.
Flow Control
Select the flow control from the drop-down menu. The
default is None.
Xon Char
Specify the character to use to start the flow of data when
Flow Control is set to Software. Prefix a decimal character
with \ or a hexadecimal character with 0x, or provide a single
printable character. The default Xon char is 0x11.
Xoff Char
Specify the character to use to stop the flow of data when
Flow Control is set to Software. Prefix a decimal character
with \ or a hexadecimal character with 0x, or provide a single
printable character. The default Xoff char is 0x13.
Gap Timer The driver forwards received serial bytes after the Gap
Timer delay from the last character received. By default, the
delay is four character periods at the current baud rate
(minimum 1 ms).
Threshold
The driver will also forward received characters after
Threshold bytes have been received.
3. Click Submit.
Line 1 Command Mode
Setting Command Mode enables the CLI on the serial line.
To configure Line 1 Command Mode:
1. Click Line 1 and Command Mode at the top of the page. The Line 1 Command
Mode page appears.