HP (Hewlett-Packard) HP-UX 11i v3 Landscape Lighting User Manual


 
460 Using Storage Expert
Rule definitions and attributes
vxse_redundancy volume_redundancy 0Volume redundancy
check. The value of 2
performs a mirror
redundancy check. A
value of 1 performs a
RAID-5 redundancy
check. The default
value of 0 performs no
redundancy check.
vxse_rootmir - - No user-configurable
variables.
vxse_spares max_disk_spare_ratio
min_disk_spare_ratio
20
10
Maximum percentage
of spare disks in a disk
group. Warn if the
percentage of spare
disks is greater than
this.
Minimum percentage
of spare disks in a disk
group. Warn if the
percentage of spare
disks is less than this.
vxse_stripes1 default _stripeunit 8k
(8KB)
Stripe unit size for
stripe volumes. Warn if
a stripe does not have a
stripe unit which is an
integer multiple of this
value.
vxse_stripes2 too_narrow_stripe
too_wide_stripe
3
16
Minimum number of
columns in a striped
plex. Warn if a striped
volume has fewer
columns than this.
Maximum number of
columns in a striped
plex. Warn if a striped
volume has more
columns than this.
Table 15-2 Rule attributes and default attribute values
Rule Attribute Default
value
Description