Apex Digital 5708009-C Portable Generator User Manual


 
5708009-C 4-49
Apex 1 to 5.5 kW Generator
86
Set point
diode 1
latch
Sets the pin diode 1 latch. Send 1 data byte.
byte 1 = latch
Note: byte 1 bits on a standard 5 pin unit:
0: Series 3
1: Series 1
2: Shunt 1
3: Shunt 2
4: Series 2
5: chamber / 50 ohm
6: Unused
7: Unused
Note: byte 1 bits on a 2 pin unit:
0: Unused
1: Series 1
2: Unused
3: Shunt 2
4: Unused
5: Unused
6: Unused
7: Unused
1 data byte
8-bit value
93
set pulsing
frequency
Sets the RF pulsing frequency in Hz. Accepts
a value of 150 to 50000. Read back with
command 193.
4 data bytes
32-bit value
1
96
set pulsing
duty cycle
Sets the RF pulsing duty ON time in
increments of 1%. This value can range from
10% to 90%. Minimum On or OFF time is >=
10uS.
2 data bytes
119
Profibus
Reset/
Explicit
Fault clear
Clears profibus fault and error code register
128
supply type
Requests the generator type; returns 4 ASCII
characters.
0 4 data bytes
4 ASCII
characters
129
supply size
Requests the output capacity of the generator;
returning packet contains 4 ASCII characters.
0 4 data bytes
4 ASCII
characters
Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes