Apex 1 to 5.5 kW Generator
16
allowable
deviation
Specifies a percentage that the generator can
be out of setpoint before it starts the out-of-
setpoint timer. Accepts a value of 1 to 99%.
(Readback command is 185.)
1 data byte
8-bit value
1
19
number of
recipe
steps
Specifies the number of recipe steps. Send 1
data byte that indicates the number of recipe
steps (0 through 5).
1 data byte
8-bit value
22
recipe step/
setpoint
Specifies setpoint for a recipe step. Send 3
data bytes.
byte 1 = recipe step number (can be 1
through 7)
bytes 2 and 3 = setpoint value (send least
significant byte first); the value must be
within the operating range of the Apex
unit (see Output Electrical
Specifications on page 3-6)
3 data bytes
8-bit value
16-bit value
23
recipe step/
run time
Sets the run time for the specified recipe step.
Send 3 data bytes.
byte 1 = recipe step number (1 through
7)
bytes 2 and 3 = run time in hundredths of
seconds or in joules (if the recipe is set
for joules mode; see CMD 28 to set
recipe type); send least significant byte
first
3 data bytes
8-bit value
16-bit value
28
recipe type
Sets the recipe for time or joules mode. Send
one data byte indicating the recipe type:
1 = time mode
2 = joules mode
1 data byte
8-bit value
40
host port
timeout
value
Sets the Host port timeout value. Accepts a
value of 2 to 500, representing 0.02 to 5.0 s.
(Readback command is 140.)
2 data bytes
16-bit value
1
Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes