Unless otherwise specified, all analog signals are 0 to 10 V while all digital signals are
5 to 24 V, opto-coupled (open-collector signals with return lines non-referenced to
ground).
Ground/Return lines are floating and need to be connected as close to the system as
possible.
SATISFYING MINIMAL REQUIREMENTS FOR THE 25-PIN USER
PORT
Regardless of whether you are controlling and monitoring the generator through the
User port or through another port, two User port signals must be satisfied for the Apex
unit to be operational: RF PWR ON (pin 4) and INTERLOCK LOOP (pins 10 and 23).
In other words, even if you are controlling the generator through the serial port
interface, the RF signal must be enabled and the interlock satisfied.
Note: If you are controlling your generator through a port other than the User port,
make sure that the control mode is set appropriately (to host mode to control
through the Host port, for example) before powering up the unit. The control
mode can be set through a Host port command.
If you are not using the User port to control or monitor the unit, you can use a
dummy or cheater plug to satisfy these two signals, thereby ignoring the User
port. To make such a plug, solder two jumpers on a mating connector: one between
pins 4 and 9 to satisfy the RF PWR ON signal and one between pins 10 and 23 to
satisfy the INTERLOCK LOOP signal. To determine the physical location of these pin
numbers on the User port, see Figure 4-1 on page 4-2.
If desired, you can add an emergency off switch in series with the RF PWR ON signal
(pin 4) or tie your system interlocks in series with the generator INTERLOCK LOOP
signal (pins 10 and 23) by following the connections for those pins described in Pin
Descriptions for the 25-Pin User Port on page 4-3 and Wiring Diagrams for the
Standard 25-Pin User Port on page 4-9.
INTERFACE CABLING REQUIREMENTS FOR 25-PIN USER PORT
The cable used to connect the Apex generators User port to the system controller
must be a shielded, 25-wire I/O cable. Twisted-pair wiring may be used but is not
mandatory. Signal losses should be minimized by keeping the cable length as short as
possible. The maximum recommended cable length between the generator and the
controller is 10 meters (33´). To minimize interference from adjacent electrical
equipment, the EMI shield in the cable must be terminated to the metal shells of the
cables connectors. Additionally, the chassis of the Apex generator must be tied to a
local earth ground through an adequately sized copper grounding strap.
PIN DESCRIPTIONS FOR THE 25-PIN USER PORT
Table 4-1 provides the connector pin descriptions for this User port interface. The pin
numbers are arranged in signal pairs.