Apex Digital 5708009-C Portable Generator User Manual


 
6-10 5708009-C
Advanced Energy
®
E050
DeviceNet
Error
DeviceNet error Verify DeviceNet
cable is connected
E051
Profibus Watch
Dog expired
PROFIBUS watch dog expired Have the master
reestablish
communications and
send a master reset
to clear the error. See
Profibus Watch Dog
Timer on page 4-61.
E054
Profibus SPC
has taken itself
off-line
Profibus SPC has taken itself off-line Cycle the Apex
units power off and
on and reestablish
communications
between the master
and the slave.
E055
Profibus
memory buffer
overflow
Profibus memory buffer overflow Increase the time
between packets
being sent to the unit
via the Profibus
master. See Host
PortProfibus on
page 4-58.
E059
Profibus master
released slave
Profibus master released slave To recover from the
off state, have a
Profibus master
establish
communications with
the Apex unit and
send a master reset
to clear the Apex
units display. See
Host Port
Profibus on
page 4-58.
E101
Measurement
PCB ID is
incorrect
This indicates a configuration error. Call AE Global
Support.
Table 6-1. Error Code Table (Continued)
Error Code Error Code Description Solution