Apex Digital 5708009-C Portable Generator User Manual


 
4-78 5708009-C
Advanced Energy
®
Forward Power Sense 0 to 10 V; 10 V = maximum rated power linear
Reflected Power Sense 0 to 10 V; 10 V = maximum reflected power linear
POS = Power on Status; 1 = power output ON, 0 = power output OFF
SPS = Setpoint Status; 1 = setpoint reached, 0 = setpoint not reached
TS = Temperature Status; 1 = GOOD, 0 = OVERTEMP
INTS = Interlock Status; 1 = satisfied, 0 = open
Note: The 16-bit AO is shifted right four bits and the remaining first four bits are
filled with 0s. This changes the 16-bit AO to a 12-bit AO with a value of
10 V = OFFF
hex
.
Note: Readbacks exceeding OFFF
hex
are limited to OFFF
hex
.
Table 4-17. Response Message
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 Forward Power Sense AI (LSB)
1 0 0 0 0 Forward Power Sense AO
(MSB)
2 Reflected Power Sense A1 (LSB)
3 0 0 0 0 Reflected Power Sense AI
(MSB)
4 Not Used AI (LSB)
5 0 0 0 0 Not Used AI (MSB)
6 Not Used AI (LSB)
7 0 0 0 0 Not Used AI (MSB)
8 INTS TS SPS POS