Apex Digital 5708009-C Portable Generator User Manual


 
4-28 5708009-C
Advanced Energy
®
Table 4-3. User Port (15-pin) Connector Pins Exclusive for Configuration E
Signal
Pin
Return
Pin
Name Signal
Type
Description
1 +24V (User Provided) Voltage
Input
+24V provided by user for
devicenet LEDs, used for
DeviceNet isolation.
See Wiring Diagram 4-24.
26REFLECTED POWER
MONITOR
Analog
output
This analog signal
provides a linearly scaled
readback of reflected
power.
0 to 10V = 0 to maximum
rated power output as
defined by configuration
PIN in Table 1-1 position
2 in Table 1-1.
See Wiring Diagram 4-25.
36FORWARD / LOAD
POWER MONITOR
Analog
output
This analog signal
provides a linearly scaled
readback of the forward
power (when the
generator is operated in
forward power regulation
mode) or the load power
(when operated in load
power regulation mode).
0 to 10V = 0 to maximum
rated power output as
defined by configuration
PIN in Table 1-1 position
3 in Table 1-1.
See Wiring Diagram 4-26.