Apex Digital 5708009-C Portable Generator User Manual


 
4-4 5708009-C
Advanced Energy
®
Table 4-1. User Port 25-Pin APEX Standard Pin Descriptions
Signal
Pin
Return
Pin
Name Signal
Type
Description
1 SETPOINT STATUS
RETURN
Digital
Output
See signal pin 14
215RFL PWR
MONITOR
Analog
output
This signal provides a linearly
scaled read back of reflected
power.
0 to 10V = 0 to maximum rated
power output as defined by
configuration PIN in Table 1-1
position 2 in Table 1-1.
See Wiring Diagram 4-2.
Pin 15 must be grounded.
316FWD/LOAD PWR
MONITOR
Analog
output
This signal provides a linearly
scaled read back of forward
power when the generator is
operated in forward power
regulation mode or the load
power when operated in the load
power regulation mode.
0 to 10V = 0 to maximum rated
power output as defined by
configuration PIN position 2 in
Table 1-1.
See Wiring Diagram 4-1. for
wiring diagram.
Pin 16 must be grounded