3-6 5708009-C
Advanced Energy
®
Output Electrical Specifications
Table 3-3 describes the output specifications for the Apex generator.
Line frequency 47 to 63 Hz
Line current Typical A/
φ and circuit breaker rating for units with
208 Vac nominal input (PIN position 3, options 0 and 3)
• 1500 W/13.56 MHz—9 A/
φ; 15 A breaker
• 3000 W/13.56 MHz—14 A/
φ; 25 A breaker
• 5500 W/13.56 MHz—25 A/
φ; 40 A breaker
Typical A/
φ and circuit breaker rating for units with
400 Vac nominal input (PIN position 3, option 1)
• 3000 W/13.56 MHz—9 A/
φ; 15 A breaker
• 5500 W/13.56 MHz—15 A/
φ; 25 A breaker
Table 3-2. Input Power Specifications (Continued)
Description PIN Option and Specification
Table 3-3. Output Specifications
Description PIN Option and Specification
Regulation modes • Forward power
• Load power
• External feedback (dc bias, for example)
Output frequency
Note: Varies according to the
option defined by PIN
position 1.
0—N/A
3—13.56 MHZ, ±0.005%