The host computer must finish one transaction with the Apex generator before it
initiates another one, either with the same unit or any other unit.
Note: The Apex generator sends data through pin 2 (TXD.D). This pin must be
connected to the receive pin (RXD.D) on the host computers PC serial
connector. The receive pin is normally pin 2 for a standard, 9-pin PC serial port
and normally pin 3 for a standard, 25-pin PC serial port.
AE BUS PROTOCOL
The AE Bus protocol uses pure binary data (nothing is coded in ASCII) and is
designed to facilitate direct communications between a host computer and the Apex
generator.
The AE Bus message packet combines chunks of information in such a way that
groups of information can be sent over communications lines at one time. Five types
of information (fields) make up communications message packets (see Figure 4-5.):
Header (address and the length of Data field)
Command (see the AE Bus command list later in this chapter)
Optional length byte
Data
Checksum (aids in error checking)
Figure 4-5. shows the organization of these data fields in the AE Bus message packet.
The subsequent paragraphs describe each data field in detail.
Figure 4-5. Graphic representation of a RS-232, AE Bus message packet
76543210765432107654321076543210 7654321076543210765432101076543
Data
(
0-255 bytes
)
C
ommand
0-FFh
Header
5-bit address
3-bit length
Optional Checksum