Advanced Energy
®
E009 contactor
failed to close
This contactor is part of the input section that
follows the interlock condition. The contactor is
closed when the interlocks are satisfied and open
when an interlock is open. If the interlocks are
satisfied and the contactor does not close, this error
code is reported.
Call AE Global
Support.
E011 Low
bus voltage
limit
The bus voltage is basically rectified input voltage.
If the bus voltage measures too low (E011) or too
high (E012), then the input voltage is too low or
high, respectively.
Send RF OFF
command to reset the
error code. If you
receive one of these
error codes, make
sure that input
voltage is within
specification see
Electrical
Specifications on
page 3-5 and send a
RF off command to
reset the error code.
E012
High bus
voltage limit
The bus voltage is basically rectified input voltage.
If the bus voltage measures too low (E011) or too
high (E012), then the input voltage is too low or
high, respectively.
If you receive one of
these error codes,
make sure that your
input voltage is
within specification
see Electrical
Specifications on
page 3-5 and send
RF OFF command to
reset the error code.
E016
Current limit
This usually indicates an internal failure. Call AE Global
Support
E017
EEPROM
failure
This verifies that the option called out in PIN
position 6 is actually installed.
Call AE Global
Support.
Table 6-1. Error Code Table (Continued)
Error Code Error Code Description Solution