Apex Digital 5708009-C Portable Generator User Manual


 
5708009-C 4-55
Apex 1 to 5.5 kW Generator
201
report unit
on events
Reports a count of unit on events
Note: The response contains 4 bytes which
represent a 32-bit count of events (LSB
first).
4 data bytes
32-bit value
202
report
output on
events
Reports a count of output on events
Note: The response contains 4 bytes which
represent a 32-bit count of events (LSB
first).
4 data bytes
32-bit value
203
report
overtemp
events
Reports a count of overtemp events
Note: The response contains 4 bytes which
represent a 32-bit count of events (LSB
first).
4 bytes
32 bit value
205
read run
time
Requests the amount of time (in seconds) that
the generator was producing output.
Note: The response contains 4 bytes which
represent a 32-bit time (LSB first). It
returns the amount of time in seconds
that the unit was producing output.
4 data bytes
32-bit value
206
read total
energy
output
Requests the total amount of energy (in kWh)
delivered by the generator.
Note: The response contains 4 bytes which
represent a 32-bit time (LSB first). It
returns the amount of energy in kilo
watt hours delivered by the unit.
4 data bytes
32-bit value
210
report fault
warnings
and
shutdowns
Returns faults, warnings, and shutdowns
Note: The response contains 1 data byte
which represents fault warnings and
shutdowns.
bit 0 indicates ripple warning
(0 = inactive, 1 = active)
bit 1 indicates ripple failure
(0 = inactive, 1 = active)
bit 2 indicates temperature rate failure
(0 = inactive, 1= active)
1 data byte
8-bit value
Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)