Apex Digital 5708009-C Portable Generator User Manual


 
4-54 5708009-C
Advanced Energy
®
188
report
recipe step
setpoints/
run times
Reports the setpoints and run times for each
recipe step. The number of data bytes
returned depends on the number of steps in
the recipe. For each recipe step, 4 data bytes
returned, indicating:
First 2 bytes = recipe step setpoint in
watts
Second 2 bytes = recipe step run time in
hundredths of seconds or joules,
depending on the recipe mode (recipe
mode is reported by CMD 188)
Varies; sends
4 data bytes
for each
recipe step
189
report
recipe
steps,
status, and
mode
Reports the number of steps in the recipe, the
status of the most recent recipe run, and the
recipe mode (time or joules). Returns 3 data
bytes:
Byte 1 = number of recipe steps
Byte 2 = recipe status:
bit 0 indicates ignition (1 = ignition
detected; 0 = ignition not detected)
bits 1, 2, and 3 indicate the most
recently completed step number
bits 47 are reserved or unassigned
Byte 3 = recipe mode (1 = time, 2 =
joule)
193
read
pulsing
frequency
Requests the RF pulsing frequency in Hz (set
with CMD 93).
Note: The response contains 4 data bytes. All
represent frequency (LSB first).
4 data bytes
32-bit value
196
read
pulsing
duty cycle
Requests the duty cycle in% ON time
Note: The response contains 2 data bytes
which represent duty cycle (LSB first)
in percent on time.
2 data bytes
16-bit value
198
read
mainframe
software
revision
level
Requests the revision level of the mainframe
software. The returning packet contains three
ASCII charactersone letter, followed by a
two-digit number. Used in conjunction with
CMD 130 to obtain the version/revision of
the mainframe software.
3 data bytes
3 ASCII
characters
Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes