Apex Digital 5708009-C Portable Generator User Manual


 
4-58 5708009-C
Advanced Energy
®
Host PortProfibus
This section describes the Profibus Host port interface. To determine if your Apex unit
has this serial interface, use the PIN from your Apex unit and the following
Configuration Note.
219
report
condensed
snapshot of
generator
data
(contd)
19,20: Real Impedance
21,22: Imaginary Impedance
221
report pin
number
Returns a string that represents the AE
product identification number (PIN). The
actual PIN length is 18 characters; however,
the response packet is 25 characters.
Note: Response contains at least 25 return
data points in packet (LSB first). the
actual PIN length is 18 characters;
however, the response packet is 25
characters.
223
report error
code
register
Retrieves the error code
Note: Response contains 1 data byte that is
the error code.
1 data byte
8-bit value
Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
This section of the manual provides information for the:
Profibus Host port option
PIN position 6, (A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17) option 2.
(When identifying the PIN position, remember that the A at the beginning of
the PIN is not counted as a position. The PIN option is the number or letter
you should look for in the specified position.)
For more information about the PIN and for a complete list of how PIN
positions correspond to Apex product options, see Table 1-1. on page 1-4.