GE PT878GC Portable Generator User Manual


 
April 2004
11-6 Specifications
Clamp-On Ultrasonic Flow Transducers
Temperature Range(s)
Standard: –40° to 130°C (–40° to 266°F)
Optional (overall range): –40° to 230°C (–40° to 446°F)
Transducer Materials
Stainless steel and plastic
Fixture Materials
Anodized aluminum blocks with stainless steel rod, chain or strap
Mountings
3/4 to 1.25 in. (76 to 42.2 mm) pipe: CFG-V1
1.25 to 4 in. (32 to 102 mm) pipe: CFG-V4
4 to 8 in. (102 to 203 mm) pipe: CFG-V8
8 to 12 in. (203 to 305 mm) pipe: CFG-V12
12 to 24 in. (305 to 609.6 mm) pipe: CFG-PI
Mounting Couplant
CPL-16
Area Classifications
Standard: General purpose
Optional: Weatherproof NEMA 4, IP65
Optional: Explosionproof Class I, Div 1, Groups C,D
Optional: Flameproof e II 2 G EEx md IIC T6–T3
(certification pending)
Note: PT878GC electronics are designed for general purpose
areas.