6. Click Next > .
The Axis Configuration Test Select frame provides two options.
Click PERFORM AXES CONFIGURATION TESTS.
The axis configuration tests allows MCT to tune the MintDrive
for use with the attached motor.
7. Using the drop-down boxes, select the exact motor
type. This information can be found stamped into the
label attached to the motor.
Important Note:
The following axis configuration tests must be
performed with the motor mechanically
disconnected from other machinery. The tests will
cause movement of the motor, so ensure that it is
safe for the motor to operate.
If it is safe for the motor to rotate, click
Coarse Tune Motor Parameters .
Click OK to confirm that you wish to begin the tests. MCT will begin the motor tests.
8. For the final test, the load should be connected to the motor.
Ensure that it is safe for the motor to operate when connected to the load.
If it is safe for the motor to operate, click OK. MCT will perform the final test.
9. Click Next > to continue with the tuning process.
Note: If an error occurs during any of the tests, an error number will appear on the error button at
the top of the window:
Click the button to see details of the error. When you have fixed the error, click Clear Errors
and then Coarse Tune Motor Parameters to restart the tests.