A SERVICE OF

logo

Power Supply 73
E-EQ-VX6RG-J VX6 Reference Guide
CMOS Battery
The LXE VX6 has a permanent 190 mAh Lithium battery installed to maintain time, date and
CMOS setup information. The lithium battery is not user serviceable and should last five years
with normal use before it requires replacement.
Fuse
The VX6 uses a 100V, 10A time delay (slow blow), high current interrupting rating fuse that is
externally accessible and user replaceable. Should it need replacement, replace with same size,
rating and type of fuse – Littlefuse 0234010 or Optifuse MSC-10A (5x20mm).
3
2
1
T10A, 125V
INPUT:
12-80VDC
6A 72W
AUDIO
ETHERNET /
USB
THIS DEVICE COM PLIES WITH PART 15 OF THE FC C RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND ( 2) THIS DEVICE MUST ACCEP T ANY
INTERFERENCE R ECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED O PERATION.
This Class A digital apparatus complies with
Canadian ICE-003.
Cet appareil num de la Classe A est
confirme l
érique
orme NMB-003 du Canadaà n
CAUTION: For continues protection against risk of fire,
replace only with same type and rating of fuse.
ATTENTION: Pour ne pas compromette la preotection
contre les risques d'incendie, remplacer par un fusible
de mmes types de mmes caractristques nominales.êêé
TENT 586239 3
1. Fuse
2. Twist in this
direction to
remove
3. Twist in this
direction to insert
Figure 2-45 Fuse Replacement
Caution:
!
Fuse has voltage on it even when power is off. Always disconnect input power
before changing fuse.