112 Control Panel Options
VX6 Reference Guide E-EQ-VX6RG-J
Autolaunch TimeSync
By default, TimeSync does not automatically run on the VX6. To enable TimeSync to run
automatically on the VX6, check this checkbox.
Synchronize with a Local Time Server
By default, GrabTime synchronizes via an Internet connection. To synchronize with a local time
server:
1. Use ActiveSync to copy GrabTime.ini from the My Device | Windows folder on the mobile
device to the host PC.
2. Edit the copy of GrabTime.ini on the host PC. Add the local time server’s domain name to
the beginning of the list of servers. You can optionally delete the remainder of the list.
3. Copy the modified GrabTime.ini file to the My Device | System folder on the mobile
device.
The System/GrabTime.ini file takes precedence over the Windows/GrabTime.ini file.
System/Grabtime.ini also persists after a coldboot; Windows/Grabtime.ini does not persist.
Misc
Options on this tab configure device specific options. Note that options not available on the VX6
are grayed out.
Figure 3-24 MX3X-VXC Options Properties / Misc Tab
CapsLock
By default, CapsLock is disabled after a warmboot. To enable CapsLock after a warmboot, check
this checkbox.
Touch Screen Disable
By default, the VX6 touchscreen is enabled. To disable the touchscreen after a warmboot, check
this checkbox.
Touch Screen Heater Disable
By default, the VX6 touchscreen heater is enabled. To disable the touchscreen after a warmboot,
check this checkbox.