Buhler 2425 Lawn Mower User Manual


 
SECTION 4 - TROUBLESHOOTING
4-9
PROBLEM POSSIBLE CAUSE CORRECTION
Tractor runs for a short time
and shuts off
Automatic shutdown mode
activated.
Partially restricted fuel line.
Check audio and visual indicators
for cause of shutdown. Contact
Buhler Versatile dealer.
Contact Buhler Versatile dealer.
Electronic monitor rotary
select switch failure (“SEL”
“OPEN”)
Open circuit on rotary select
switch for electronic instrument
control system.
Reconnect plug on back of switch.
Replace faulty switch.
Transmission speed sensor
“OPEN” or “SHCR”
Malfunction in sensor or sensor
wiring.
Sensor is unplugged, reconnect.
Sensor wiring is damaged, repair
wiring.
Contact Buhler Versatile dealer.
Engine speed sensor
“OPEN” or “SHCR”
Malfunction in sensor or sensor
wiring.
Sensor is unplugged, reconnect.
Sensor wiring is damaged, repair
wiring.
Contact Buhler Versatile dealer.
Electrical system high/low
voltage
Loose or corroded terminal
connections.
Shorted out electrical system.
Sulfated batteries.
Loose or worn belt.
Clean and tighten connections.
Contact Buhler Versatile dealer.
Check each battery open circuit
voltage for 12.6 volts minimum.
Check electrolyte level and
specific gravity.
Check alternator belt tension.
Replace belt if required.
Batteries will not charge Loose or corroded terminal
connections.
Sulfated batteries.
Loose or worn belt.
Clean and tighten connections.
Check each battery open circuit
voltage for 12.6 volts minimum.
Check electrolyte level and
specific gravity.
Check alternator belt tension.
Replace belt if required.