Buhler 2425 Lawn Mower User Manual


 
SECTION 2 - OPERATION
2-105
Caret 1/ Pos. A Acre accumulator
This displays the acres covered in XXX.Xformat
based on the implement width and the ground
speed. The display increments as long as the
implement status is down. When the implement
status is up, the acres value stops accumulating
and flashes the value when the acre
accumulator caret is selected.
Caret 2/ Pos. B Acres per hour
This displays the calculated acres covered per
hour in XXX.X format based on the implement
width and ground speed. This display updates
as long as the implement status is down. When
the implement status is up, the acre per hour
value will display “.0” and an alarm will sound for
3 seconds to indicate that the implement is up.
Caret 3/ Pos. C Distance Accumulator
(Feet)
This accumulates feet from the radar input in an
XXXX format. To start and stop the distance
accumulator, select a distance accumulator
caret function and press the start/stop touch
switch. To reset the distance accumulator press
and hold the start/stop touch switch until the
LCD blinks and displays “0”. The distance
accumulators (feet and meters) are tied
together, so starting, stopping, or resetting
either distance accumulator does the same
action on the other caret function. The
accumulated distance flashes when
accumulation stops.
Caret 4/ Pos. D Percent slip
This displays the percentage difference
between the radar input and the sensor input
from the transmission in XXXX format. The slip
caret flashes when the slip is greater than the
slip alarm percentage regardless of what
function is being viewed. When the caret is
flashing, a continuous alarm sounds until the
slip drops below the slip alarm percentage.
While in the alarm condition, other carets can
still selected and viewed; however the slip caret
will continue to flash until the slip drops below
the slip alarm value. The default alarm
percentage is 15%.
Caret 5/ Pos. E Distance Accumulator
(Meters)
This accumulates meters from the radar in an
XXXX format. To start and stop the distance
accumulator, select a distance accumulator
caret function and press the start/stop touch
switch. To reset the distance accumulator press
and hold the start/stop touch switch until the
LCD blinks and displays “0”. The distance
accumulators (feet and meters) are tied
together, so that starting, stopping, or resetting
either distance accumulator does the same to
the other caret function. The accumulated
distance will flash when accumulation has
stopped.
Caret 6/ Pos. F Hectares per hour
This displays the calucated hectares covered
per hour in XXX.X format based on the
implement width and ground speed. This
display updates as long as the implement status
is down. When the implement status is up the
hectare per hour value will display “.0” and an
alarm will sound for 3 seconds to indicate that
the implement is up.
Caret 7/ Pos. G Hectare accumulator
This will display the hectares covered in XXX.X
format based on the i mplement width and the
current speed in XXX.X format. This display will
increment as long as the implement status is
down. When the implement status is up the
hectares value will stop accumulating and flash
that value when the hectare accumulator caret
is selected.
Slip Alarm
When the percent slip is above the alarm
percent setting a continuous audible alarm
sounds and the slip caret flashes until the
percent slip drops below the alarm value. If the
percent slip caret is selected during an alarm
condition, the current slip value will be displayed
and updated. The maximum value that can be
displayed is 30%.
NOTE: Whether in Percent Slip mode or not,
when the alarm percentage is reached, the TPM
will activate the alarm.
Zeroing Slip Function
To set the zero slip, select the percent slip caret
and drive the tractor at a constant speed in a
zero slip condition then press and hold the reset
touch switch for three seconds until the LCD
blinks.
Acres Accumulator Zeroing Function
To reset the acres accumulators to zero, select
the acres area accumulator and press and hold
the reset touch switch for three seconds until the
LCD blinks and displays “.0”. This resets the
acre area accumulator to zero.