Buhler 2425 Lawn Mower User Manual


 
SECTION 3 - LUBRICATION AND MAINTENANCE
3-75
AS REQUIRED
Lower the ether canister, 1, into the top of the
solenoid valve, 2; screw it in clockwise.
Tighten the ether canister hand tight only.
Once the ether canister is screwed into the
solenoid valve, secure the canister firmly by
attaching the hose clamp, 3, to the bracket and
around the canister. Tighten the hose clamp.
CAUTION: STARTING FLUID IS HIGHLY
FLAMMABLE. DO NOT USE NEAR FIRE,
SPARKS, OR FLAMES. BE SURE ALL
OPERATORS READ THE CAUTIONARY
INFORMATION ON THE CANISTER.
CAUTION: THE ETHYL ETHER USED AS
COLD START FLUID IS EXTREMELY
FLAMMABLE, TOXIC, AND FATAL IF
SWALLOWED. AVOID CONTACT WITH EYES
OR SKIN. AVOID BREATHING THE FUMES.
IF SWALLOWED, DO NOT INDUCE
VOMITING. CALL DOCTOR IMMEDIATELY.
IF COLD START FLUID ENTERS EYES OR
FUMES I RRITATE EYES, WASH EYES WITH
LARGE QUANTITIES OF CLEAN WATER FOR
15 MINUTES. CONTACT A DOCTOR,
PREFERABLY AN EYE SPECIALIST,
IMMEDIATELY.
Figure 3-124
1
2
3
OPERATION 74
Drain the Fuel Tanks
The fuel tanks can be drained by opening the
petcock, 1, located on the inside of each tank.
Allow the diesel fuel to drain and retighten the
petcock. Dispose of the fuel (if necessary)
according to local laws and regulations.
Figure 3-125
1