SECTION 2 - OPERATION
2-85
The operator can cancel the audible alarm and
the “VOLTS” only display on the lower portion of
the monitor by pressing the acknowledge/reset
button. The lower portion of the monitor will
revert back to its previous display based on the
position of the rotary select switch, but “VOLTS”
will flash in the lower portion of the monitor along
with the selected display. The audible alarm will
not return until the ignition switch is turned to the
“OFF” position and the tractor is restarted.
High/low electrical system voltage is considered
a non-critical alarm function and will not cause
the electronic monitor to go into the “STOP”
mode or cause the automatic shutdown to
activate.
ATTENTION: It is important that the operator
shut the tractor off and find out the cause of the
high/low electrical system voltage indication.
Take corrective action immediately to prevent
damage to the electrical system.
Figure 2-114