Buhler 2425 Lawn Mower User Manual


 
SECTION 2 - OPERATION
2-95
3. Locate the small pin connector, 1, for the
shutdown circuit. The pin connector is
between the 3-amp turn signal fuse and the
10-amp tail lamp fuse. Remove the 3-amp
fuse and 10-amp fuse from their locations to
give better access to the small pin connector.
Figure 2-126
1
4. Using a small pair of needle-nose pliers, pull
straight upward on the small pin connector, 1,
and reinstall it so the front two pins are
connected together. The rear pin will now be
bare. Reinstall the 3-amp and 10-amp fuses.
Figure 2-127
1
5. Locate the shutdown relay position, 1, ( the
fourth relay from the right), and install a relay
(part #9706720 purchased from your Buhler
Versatile dealership). Press the relay firmly
into the electrical control panel.
6. Reinstall the cover onto the electrical control
panel.
7. Reconnect the battery cables.
To disable the shutdown feature, follow this
procedure in reverse order.
Figure 2-128
1