Buhler 2425 Lawn Mower User Manual


 
SECTION 3 - LUBRICATION AND MAINTENANCE
3-70
AS REQUIRED
The fuse and relay panel is clearly marked for all
electrical functions. There are no circuit breakers
on Buhler Versatile 4WD tractors. Not all relays
that are used in the electrical system are housed
in the fuse and relay panel area. If equipped with
a powershift transmission, the neutral relay is
located near the powershift control under the RH
console. The brake/tail light relays (2 used) are
located near the lower RH rear corner of the
CAB, below the fuse/relay panel. In-line fuses for
the optional ‘Back-- up Alarm’, ‘Beacon Light’,
‘Motorized Flow Control’ are located beside the
fuse/relay panel.
There are extra fuses, 1, located at the front of
the fuse panel and a fuse removing tool, 2, is
located in the right front corner of the panel. The
fuses are clearly marked for amperage rating.
Figure 3-114
1
2
OPERATION 66
Check the Throttle Settings
DANGER: ANY THROTTLE ADJUSTMENT
MUST BE MADE WITH THE ENGINE OFF AND
THE PARK BRAKE APPLIED.
The throttle settings for the engine are controlled
by the electronic module, 1, on the engine. The
low idle speed is 850 -- 900 RPM. High idle speed
is 2225 ±50 RPM. All settingsare adjustable only
by an authorized Buhler Versatile dealer or
Cummins dealer/distributor.
(2360 and 2425 models illustrated)
Figure 3-115
1