Anritsu 683XXB Portable Generator User Manual


 
3. External Unlocked Wide FM Mode Sensitivity
calibration is accomplished by adjusting the FM
Variable Gain Control DAC to obtain a 200 MHz
FM deviation at frequencies of 5 GHz and
15 GHz. The modulating signal input is from the
external Function Generator.
Perform the calibration as follows:
a.
At the
$ prompt, type: calterm 124 and
press <ENTER>.
b. Set up the Function Generator for a 0.1 Hz
square wave with an output level of ±1 volt
±0.002 volts (2 volts peak to peak).
c. On the Spectrum Analyzer, set the Span/Div to
50 MHz per division.
d. On the computer keyboard, use the ‘, 1, 2, and
3 keys to increment and the 7, 8, 9, and 0 keys
to decrement the value of the DAC’s setting.
Start calibration by pressing the key.
e. While observing the Spectum Analyzer display,
adjust the value of the DAC’s setting to obtain
a 200 MHz peak to peak deviation. This is the
coarse adjustment.
f. On the Spectrum Analyzer, set the Span/Div to
5 MHz per division and adjust the center fre-
quency control to position the low carrier at
the center of the display. Note the frequency
reading.
g. Now, adjust the center frequency control to po
-
sition the high carrier at the center of the dis
-
play. Note the frequency reading.
h. The difference between these two frequencies
is the actual peak-to-peak frequency deviation.
It should be 200 MHz ±0.5 MHz. If not, fine ad
-
just the value of the DAC’s setting to obtain
this deviation.
i.
When finished setting the DAC, press
Q on the
keyboard to go to the next calibration step (ad
-
justing the DAC to obtain a 200 MHz deviation
at 15 GHz).
When the DAC has been completely adjusted,
the program will exit to the
$ prompt.
j. Record step completion on the Test Record.
4-46 682XXB/683XXB MM
FM
CALIBRATION CALIBRATION