Quantum Data 801GC, 801GF, 801GX Portable Generator User Manual


 
6-161
SEQK SEQuence Kill
Classification: Sequence memory management
Command Syntax: SEQK <name>
Limits: <name> = a valid MS-DOS filename
(8 characters minus any extension)
Query Syntax: SEQK? <name>
Limits: <name> = a valid MS-DOS filename
(8 characters minus any extension)
Query Response: 0 or 1
Description: The SEQK command deletes a sequence by name. The query
returns a one (1) if the named sequence can be deleted. If sequence
is read-only or nonexistent, the query returns a zero (0).
Other Required Cmds: None
Example: SEQK MY_SEQ // Delete seq called
// "MY_SEQ"
SEQL SEQuence Load
Classification: Sequence memory management
Command Syntax: SEQL <name>
Limits: <name> = a valid MS-DOS filename
(8 characters minus any extension)
Query Syntax: SEQL? <name>
Limits: <name> = a valid MS-DOS filename
(8 characters minus any extension)
Query Response: 0 or 1
Description: The SEQL command copies the sequence having a name equal
to <name> from sequence memory into the sequence edit buffer.
The query returns a one (1) if the named sequence can be loaded,
otherwise a zero (0) is returned.
Other Required Cmds: An SEQU command must be executed after the SEQL command
to start running the sequence.
Example: SEQL MY_SEQ // Load "MY_SEQ" dir in
// edit buffer
SEQU // Start running the sequence in
// the buffer