Quantum Data 801GC, 801GF, 801GX Portable Generator User Manual


 
6-150 Chapter 6: Programming
Model 801GC, 801GF & 801GX¥Rev. A
MODE communications MODE
Classification: System parameter setting
Command Syntax: MODE <baud> [<parity> [<data > [<stop> [<handshake> [<
protocol>]]]]]
Limits: <baud rate>
300, 600, 1200, 2400, 4800, 9600, 19200 or 38400 bits/
sec
<parity>
N = None, E = Even or O = Odd
<# data bits>
7 or 8
<# stop bits>
1 or 2
<handshake>
N = None, S = Software (XON/XOFF) or
H = Hardware (CTS/RTS)
< protocol >
N = None, Y=Y-Modem
Query Syntax: MODE?
Query Response: <baud> <parity> <data > <stop> <handshake> < protocol>
or
<ISA addr>
Description: The MODE command is normally used to set the serial port
communications parameters of a stand-alone model generator.
The changes take effect as soon as the command is entered. The
command has no affect on the ISA addressing configuration of
the -ISA model generators. The MODE? query returns the current
serial port communications settings of a stand-alone generator
or the ISA address of an -ISA model generator.
Other Required Cmds: None
Examples: MODE 9600 N 8 1 H N // Set a stand
// alone generator to communicate
// at 9600 Baud, No parity, 8 data
// bits, 1 stop bit, RTS//CTS
// handshaking and No protocol
or
MODE 2400 // Change only the baud rate