Quantum Data 801GC, 801GF, 801GX Portable Generator User Manual


 
6-57
malfunctioning. The “Making Connection” chapter
has information on display codes that are used by
some systems.
A format can be programmed to check these lines
and report the results to the operator.
The DCBM parameter determines which of up to 4
sense lines will be tested. A value of 15 will test all
4 lines. A value of 7 will test 3.
The DCEX parameter is the display code number
that you are expecting to get back from a particular
display. The actual value that is read back is shown
in the “Format” test image.
The 801G* does not use the display code data to
change its own operating modes. The DCBM and
DCEX parameters are only used to provide in-
formation to the operator so that they may com-
pare the expected and actual results.
Outputs Control
The last set of format parameters allow you to de-
termine which outputs are active when the operator
first selects the format from memory.
In the current version of firmware, the status of
the “Outputs” button has priority over individual
gating controls. Selecting a format while the
outputs are turned off will keep all of the out-
puts off until the button is pressed. Selecting a
format while the outputs are turned on will ac-
tivate all of the outputs that have been gated on
in the format.