6-8 Chapter 6: Programming
Model 801GC, 801GF & 801GX¥Rev. A
should be stable and legible on your display. You
should also double check the active video data to
make sure you have at least 640 pixels by 480 lines
of active video.
Once you have confirmed proper operation, switch
the 801G* to its programming mode:
1) Turn the 801G*’s power off.
2) Turn the power back on while holding down
the “Image” button on the front panel.
3) Select a compatible format using the Format
knob.
4) Rotate the “Image” knob. You will see
additonal image names appear on the LCD win-
dow. Most are GUI editor screens that will ap-
pear as text on your display screen. Pressing the
“Image” button so that it is lit will activate the
editor that is being displayed.
You will also see an image name of “CustmImg”
in the list. It is a default custom image that can
be edited and saved using another name. Press-
ing the “Image” button will activate the custom
image editor.
The generator’s front panel knobs and buttons per-
form different functions in the GUI screens when
an editor is activated. In most cases, the upper “For-
mat” knob is used to select an item in the screen to
be modified. The lower “Image” knob usually modi-
fies or tweaks the selected item. The current button
functions are identified by eight inverted text labels
at the bottoms of the screens. Available button func-
tions are shown with an intensified background on
the screen and lit buttons on the front panel. Un-
available button functions are dimmed on the screen
and front panel. More information on specific knob
and button functions will be given in the discussion
of each editor.
To switch the 801G* out of the GUI programming
mode, cycle the power without holding any of the
buttons down.