Quantum Data 801GC, 801GF, 801GX Portable Generator User Manual


 
6-144 Chapter 6: Programming
Model 801GC, 801GF & 801GX¥Rev. A
IMGS IMaGe Save
Classification: Image memory management
Command Syntax: IMGS
Query Syntax: None
Description: The IMGS command saves the current contents of the generators
custom image edit buffer back to the memory location from
which it was originally read.
Other Required Cmds: None
Example: IMGS
IMGU IMaGe Use
Classification: Image memory management
Command Syntax: IMGU
Query Syntax: IMGU?
Query Response: <location>
Description: The IMGU command draws an image based on the current
contents of the image . The IMGU? query returns the image
memory location <location> from which the current contents of
the image were read. See the IMGR command for setting the
contents of the image.
Other Required Cmds: None
Example: IMGL BriteBox // Select the BriteBox
// test image
IMGU // Draw the selected test image
INIT INITialize to factory default settings
Classification: Direct processor control
Command Syntax: INIT
Query Syntax: None
Description: The INIT command restores the contents of all of the generators
RAM storage locations to factory-default conditions. The generator
then goes through a complete self-test and self-calibration
procedure.
WARNING: The INIT command permanently and irreversibly
removes all user-created formats, custom images, test sequences
and directories from memory.
Other Required Cmds: None
Example: INIT