Toshiba VF-S11 Portable Generator User Manual


 
E6581160
70
8
8. Specifications
8.1 Models and their standard specifications
Q Standard specifications
Item Specification
Input voltage 3-phase 240V
Applicable motor (kW) 0.2 0.4 0.55 0.75 1.5 2.2 4.0 5.5 7.5 11 15
Type VFS11
Form 2002PM 2004PM 2005PM 2007PM 2015PM 2022PM 2037PM 2055PM 2075PM 2110PM 2150PM
Capacity (kVA) Note 1) 0.6 1.3 1.4 1.8 3.0 4.2 6.7 10 13 21 25
Rated output/current
(A) Note 2)
1.5
(1.5)
3.3
(3.3)
3.7
(3.3)
4.8
(4.4)
8.0
(7.9)
11.0
(10.0)
17.5
(16.4)
27.5
(25.0)
33
(33)
54
(49)
66
(60)
Output voltage Note 3) 3-phase 200V to 240V
Rating
Overload current rating 150-60 seconds, 200%-0.5 second
Voltage-frequency 3-phase 200V to 240V - 50/60Hz
Power
supply
Allowable fluctuation Voltage + 10%, -15% Note 4), frequency ±5%
Protective method IP20 Enclosed type (JEM1030)
Cooling method Self-cooling Forced air-cooled
Color Munsel 5Y-8/0.5
Built-in filter Basic filter
Item Specification
Input voltage 1-phase 240V 3-phase 500V
Applicable motor (kW) 0.2 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15
Type VFS11S VFS11
Form 2002PL 2004PL 2007PL 2015PL 2022PL 4004PL 4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL
Capacity (kVA) Note 1) 0.6 1.3 1.8 3.0 4.2 1.1 1.8 3.1 4.2 7.2 11 13 21 25
Rated output current
(A) Note 2)
1.5
(1.5)
3.3
(3.3)
4.8
(4.4)
8.0
(7.9)
11.0
(10.0)
1.5
(1.5)
2.3
(2.1)
4.1
(3.7)
5.5
(5.0)
9.5
(8.6)
14.3
(13.0)
17.0
(17.0)
27.7
(25.0)
33
30
Rated output voltage Note 3) 3-phase 200V to 240V 3-phase 380V to 500V
Rating
Overload current rating 150-60 seconds, 200%-0.5 second 150-60 seconds, 200% -0.5 second
Voltage-current 1-phase 200V to 240V – 50/60Hz 3-phase 380V to 500V - 50/60Hz
Power
supply
Allowable fluctuation
Voltage + 10%、-15% Note 4),
frequency±5
Voltage + 10%, -15% Note 4), frequency ±5%
Protective method, IP20 Enclosed type (JEM1030) IP20 Enclosed type (JEM1030)
Cooling method Self-cooling
Forced air-
cooled
Forced air-cooled
Color Munsel 5Y-8/0.5 Munsel 5Y-8/0.5
Built-in filter EMI filter EMI filter
Item Specification
Input voltage 3-phase 600V
Applicable motor (kW) 0.75 1.5 2.2 4.0 5.5 7.5 11 15
Type VFS11-
Form 6007P 6015P 6022P 6037P 6055P 6075P 6110P 6150P
Capacity (kVA) Note 1) 1.7 2.7 3.9 6.1 9 11 17 22
Rated output/current
(A) Note 2)
1.7
(1.5)
2.7
(2.4)
3.9
(3.5)
6.1
(5.5)
9.0
(8.1)
11.0
(9.9)
17.0
(15.3)
22.0
(19.8)
Output voltage Note 3) 3-phase 525V to 600V
Rating
Overload current rating 150-60 seconds, 200%-0.5 second
Voltage-frequency 3-phase 525V to 600V - 50/60Hz
Power
supply
Allowable fluctuation Voltage + 10%, -15% Note 4), frequency ±5%
Protective method IP20 Enclosed type (JEM1030)
Cooling method Forced air-cooled
Color Munsel 5Y-8/0.5
Built-in filter No filter