Torque boost parameters 1
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
E6581158
0: Auto-tuning disabled
1: Initialization of H (reset to 0)
H
0400 Auto-tuning - -
2: Auto-tuning enabled
(after execution: 0)
0
H
0401 Slip frequency
gain
% 1/1 0-150 50
H
0402 Automatic torque
boost value
% 0.1/0.1 0.0-30.0 * 1
H
0415 Motor rated
current
A 0.1/0.1 0.1-100.0 * 1
H
0416 Motor no-load
current
% 1/1 10-90 * 1
H
0417 Motor rated speed min-1 1/1 100-32000 1410(WP)
1710
(WN, AN)
H
0418 Speed control
response
coefficient
- 1/1 1-150 40
H
0419 Speed control
stability coefficient
- 1/1 1-100 20
5.11
6.17.1
*1 : Default values vary depending on the capacity. See the table of page 64.
Input/output parameters 2
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
E6581158
H
0470 VIA input bias - - - -
H
0471 VIA input gain - - - -
H
0472 VIB input bias - - - -
H
0473 VIB input gain - - - -
6.5.4
Torque boost parameters 2
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
E6581158
H
0480 Exciting current
coefficient
% 1/1 100-130 100
H
0485 Stall prevention
control coefficient 1
- 1/1 10-250 100
H
0492 Stall prevention
control coefficient 2
- 1/1 50-150 100
H
0494 Motor adjustment
coefficient
- 1/1 0-200 * 1
H
0495 Maximum voltage
adjustment
coefficient
% 1/1 90-110 104
H
0496 Waveform
switching
adjustment
coefficient
kHz 0.1/0.01 0.1-14.0 0.2
5.11
6.17.2
*1 : Default values vary depending on the capacity. See the table of page 64.