Toshiba VF-S11 Portable Generator User Manual


 
E6581160
57
7
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
E6581158
0: Supply voltage uncorrected, output
voltage limited
1: Supply voltage corrected, output
voltage limited
2: Supply voltage uncorrected, output
voltage unlimited
H
0307 Supply voltage
correction
(limitation of
output voltage)
--
3: Supply voltage corrected, output
voltage unlimited
2
(WP, WN)
3 (AN)
6.13.6
H
0308 Dynamic braking
resistance
0.1/0.1 1.0-1000 * 1 6.13.4
H
0309 Dynamic braking
resistor capacity
kW 0.01/0.01 0.01-30.00 * 1 6.13.4
H
0311 Reverse-run
prohibition
- - 0: Forward/reverse run permitted
1: Reverse run prohibited
2: Forward run prohibited
0 6.13.7
H
0312 Random mode - - 0: Disabled
1: Automatic setting
06.12
0: Carrier frequency not reduced
automatically
1: Carrier frequency reduced
automatically
2: Carrier frequency not reduced
automatically
Support for 500V/600V models
H
0316 Carrier frequency
control mode
selection
--
3: Carrier frequency reduced
automatically
Support for 500V/600V models
16.12
H
0320 Droop gain
1/1 0-100 0 6.14
H
0323 Droop insensitive
torque band
1/1 0-100 10 6.14
H
0342 Braking mode
selection
- - 0: Disabled
1: Enabled (forward run)
2: Enabled (reverse run)
3: Enabled (operating direction)
06.15
H
0343 Release
frequency
Hz 0.1/0.01 H-20.0 3.0
H
0344 Release time s 0.01/0.01 0.00-2.50 0.05
H
0345 Creeping
frequency
Hz 0.1/0.01
H-20.0
3.0
H
0346 Creeping time s 0.01/0.01 0.00-2.50 0.10
H
0359 PID control
waiting time
s 1/1 0-2400 0 6.16
H
0360 PID control - - 0: Disabled, 1: Enabled 0
H
0362 Proportional gain - 0.01/0.01 0.01-100.0 0.30
H
0363 Integral gain - 0.01/0.01 0.01-100.0 0.20
H
0366 Differential gain - 0.01/0.01 0.00-2.5 0.00
*1 : Default values vary depending on the capacity. See the table of 64.