Toshiba VF-S11 Portable Generator User Manual


 
E6581160
47
6
[Example of wiring]
Control wiring (Shielded cables)
Motor wiring (Shielded cables)
Braking resistor wiring (Shielded cables)
Power supply wiring
FL relay wiring
VF-S11
To relay
Grounding terminal screw
(Note 1)
EMC plate
Note 1: Strip and earth the shielded cable, following the example shown in Fig.
Strip the cable and fix it to the metal plate by means
of a metal saddle for electrical work or equivalent.
Shielded cable
6.1.3 About the low-voltage directive
The low-voltage directive provides for the safety of machines and systems. All Toshiba inverters are CE-marked
in accordance with the standard EN 50178 specified by the low-voltage directive, and can therefore be installed in
machines or systems and imported without problem to European countries.
Applicable standard: EN50178
Electronic equipment for use in power installations
Electronic equipment for use in power installations
Pollution level: 2 (5.2.15.2)
Overvoltage category: 3
240V class - 3.0mm (5.2.16.1)
500V class - 5.5mm (5.2.16.1)