7. Table of parameters and data
For details on the function of each parameter, refer to the full version of English manual (E6581158).
7.1 User parameters
Title Function Unit
Minimum
setting unit
Panel/Comm
unication
Adjustment range Default setting
User
setting
Reference
E6581158
HE
Operation
frequency of
operation panel
Hz 0.1/0.01 NN-WN 0.0 3.2
7.2 Basic parameters
Four navigation functions
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
E6581158
CWJ
- History function - - Displays parameters in groups of five
in the reverse order to that in which
their settings were changed.
* (Possible to edit)
- 4.1.4
CW
0000 Automatic
acceleration/
deceleration
- - 0: Disabled (manual)
1: Automatic
2: Automatic (only at acceleration)
0 5.1.1
CW
0001 Torque boost
setting macro
function
- - 0: Disabled
1: Automatic torque boost + auto-
tuning
2: Vector control + auto-tuning
3: Energy saving + auto-tuning
05.2
CW
0040 Parameter setting
macro function
- - 0: Disabled
1: Coast stop
2: 3-wire operation
3: External input UP/DOWN setting
4: 4-20 mA current input operation
05.3
Basic parameters
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
E6581158
EOQF
0003 Command mode
selection
- - 0: Terminal board
1: Operation panel
15.4
7.2
HOQF
0004 Frequency setting
mode selection 1
- - 0: Built-in potentiometer
1: VIA
2: VIB
3: Operation panel
4: Serial communication
5: UP/DOWN from external contact
6: VIA + VIB (Override)
05.4
6.5.1
7.1