Dukane 403-574-01 Portable Generator User Manual


 
Page  88 
iQ Series, Ultrasonic Generator/Power Supply LS User’s Manual
Dukane Manual Part No. 403-574-01
+5V TO +24V PNP CONVERSION
+5V
IN 1 @ 0V = ON
IN 1 @ 5V = OFF
GND
IN 2 @ 5V = ON
IN 2 @ 0V = OFF
IN 3 @ 0V = ON
IN 3 @ 5V = OFF
ACTIVE HIGH TTL
ACTIVE LOW TTL
OPEN COLLECTOR
WITH PULL-UP
RESISTOR
OPEN COLLECTOR
IN 4 @ 5V = OFF
IN 4 @ 0V = ON
SPECIFICATIONS:
INPUTS:
MINIMUM VOLTAGE: 5.0 Vdc
CURRENT: 1.5mA @ 5.0 Vdc / 9.5mA @ 24.0 Vdc
MAXIMUM VOLTAGE: 30.0 Vdc
MAXIMUM CURRENT: 50mA
MAXIMUM VOLTAGE: 30.0 Vdc
MINIMUM VOLTAGE: 5.0 Vdc
OUTPUTS:
VOLTAGE DROP ( + TO - ): 1.0 Vdc MAX
NOTES:
OUTPUTS SHOULD NOT BE CONFIGURED TO SINK A TTL LOAD TO
GROUND. A RELAY CONNECTION SHOULD BE USED INSTEAD.
1:
0VDC24VDC
0VDC24VDC
LOAD
LOAD
110-4397
IN 1
IN 1 COM
IN 2
IN 2 COM
IN 3
IN 3 COM
IN 4
IN 4 COM
OUT 1+
OUT 1-
OUT 2+
OUT 2-
OUT 3+
OUT 3-
OUT 4+
OUT 4- LOAD
LOAD
+5V
+5V
Figure 10-19 +5V to +24V PNP Conversion