MPC Interface Status LEDs
System Status
When the system is powered and ready, the front panel
SYSTEM STATUS LED lights up, and becomes
GREEN (E in Figure 10 - 9).
If this LED is lit with a YELLOW/ORANGE color, a
recoverable fault condition has tripped. This indicates
that the system is operational, but a fault condition has
occurred preventing normal operation. Examples of this
type of fault would be a generator overload that will
automatically reset when the next weld cycle begins, or
the automation control system is selecting a channel that
doesn’t exist - for instance, trying to select channel 10
for an 8 channel system
If this LED lights up RED, a hardware fault has been
sensed, and the unit should be returned to Dukane for
servicing.
Probe Selection Status
The PROBE SELECTION STATUS LED (F in
Figure 10 - 9) lights up GREEN indicating it is the
selected probe.
A probe’s LED turns to RED (from GREEN) when
ultrasonic power is activated.
F
E
Figure 10- 9 MPC Interface Status LEDs