Dukane 403-574-01 Portable Generator User Manual


 
Page  58 
iQ Series, Ultrasonic Generator/Power Supply LS User’s Manual
Dukane Manual Part No. 403-574-01
System Test
To test the system’s ultrasound operation, perform the
following steps.
Step 1. For this test, the generator must be ONLINE. If
the OFFLINE LED is showing yellow (D in Fig-
ure 7-3) press the ON/OFFLINE key.
The ONLINE LED (G in Figure 7-5) should turn
green.
Step 2. Connect a probe to the generator ultrasonic out-
put.
Step 3. Place the probe so that the tip of the horn is not
in contact with anything. If you are using a hand
probe, you may feel a slight vibration or sensation
in your hand. This is normal. There should not be
any loud or unusual noise.
Step 4. Momentarily press the TEST control key (E in
Figure 7-5).
Step 5. The rst segment LED of the SYSTEM POWER
OUTPUT LEVEL bar graph (H in Figure 7-5)
turns green. The probe will operate as long as the
TEST key is pressed.
Step 6. When the TEST key is released, the SYSTEM
POWER OUTPUT LEVEL bar graph turns off
(gray). This test cannot be performed with the
generator OFFLINE.
CAUTION
Any unusually loud noise
from the probe stack in-
dicates that it has been
improperly assembled.
Check the probe stack
for c orrect assem-
bly and proper torque.
LOAD
8060 100
OVER
400 20
SYSTEM POWER OUTPUT LEVEL
SYSTEM OPERATING MODE
LOAD
8060 100
OVER
400 20
SYSTEM POWER OUTPUT LEVEL
SYSTEM OPERATING MODE
ON
LINE
OFF
LINE
POWER
TEST
# 1 PART COUNT 125
WELD TIME 0.080 S
POWER 1050 W
ENERGY 350 J
ON
LINE
# 1 PART COUNT 125
WELD TIME 0.080 S
POWER 1050 W
ENERGY 350 J
I
N
F
O
O
N
/
O
F
F
L
I
N
E
T
E
S
T
C
A
N
C
E
L
E
N
T
E
R
G
H
E
Figure 7 - 5 System Test