Dukane 403-574-01 Portable Generator User Manual


 
Page  50 
iQ Series, Ultrasonic Generator/Power Supply LS User’s Manual
Dukane Manual Part No. 403-574-01
HOW TO - Weld by Time
1. Press CANCEL until you see the Main Menu screen as
it is shown here.
Move the selection indicator to PROCESS SETUP.
2. Press ENTER and you will see the screen as shown
here.
3. Select PROCESS CONTROL, and press ENTER.
With no option boards installed in the generator, you will
get a “WELD BY” choice of iQ SYSTEM or
AUTOMATION.
4. Select iQ SYSTEM, and press ENTER.
5. Select WELD CONTROL.
6. Select WELD BY TIME.
7. Select the digits with the RIGHT and LEFT arrows. Use
the UP and DOWN arrows to select the value [time, in
seconds] of each digit.
8. When done with the time entry, press ENTER, and an
ENTRY ACCEPTED message will appear.
# 1:
OPERATE MODE
PROCESS SETUP
HARDWARE SETUP
PROCESS SETUP
PROCESS CONTROL
PROCESS LIMITS
UTILITIES
AUTOMATED PROBE
WELD CONTROL BY
iQ SYSTEM
AUTOMATION
WELD CONTROL
HOLD CONTROL
AFTERBURST CONTROL
AMPLITUDE CONTROL
WELD BY TIME
WELD BY PEAK POWER
WELD BY ENERGY
WELD TIME
0.000 S
SELECT DIGIT
SELECT VALUE
NOTE
In the above example we selected Time as the primary method of weld control.
Next, the time of the weld was set (in seconds). The program will then ask
the operator to choose and set a SECONDARY weld control.
Choices the operator can make: Disable a secondary weld control, or enable
either Peak Power, or Energy as the secondary weld control.