GE 489 Portable Generator User Manual


 
6-26 489 Generator Management Relay GE Multilin
6.3 MODBUS MEMORY MAP 6 COMMUNICATIONS
6
2525 RTD #5 TRIP 0 to 2 1 F115 0
2526 RTD #5 TRIP VOTING 1 to 12 1 F122 5
2527 ASSIGN TRIP RELAYS (1-4) 0 to 3 1 F50 1
2528 RTD #5 TRIP TEMPERATURE 1 to 250 1 °C F1 155
2529 RTD #5 NAME 0 to 8 1 F22 _
RTD TEMPERATURE / RTD #6
2560 RTD #6 APPLICATION 0 to 4 1 F121 1
2561 RTD #6 ALARM 0 to 2 1 F115 0
2562 ASSIGN ALARM RELAYS (2-5) 1 to 4 1 F50 16
2563 RTD #6 ALARM TEMPERATURE 1 to 250 1 °C F1 130
2564 RTD #6 ALARM EVENTS 0 to 1 1 F105 0
2565 RTD #6 TRIP 0 to 2 1 F115 0
2566 RTD #6 TRIP VOTING 1 to 12 1 F122 6
2567 ASSIGN TRIP RELAYS (1-4) 0 to 3 1 F50 1
2568 RTD #6 TRIP TEMPERATURE 1 to 250 1 °C F1 155
2569 RTD #6 NAME 0 to 8 1 F22 _
RTD TEMPERATURE / RTD #7
25A0 RTD #7 APPLICATION 0 to 4 1 F121 2
25A1 RTD #7 ALARM 0 to 2 1 F115 0
25A2 ASSIGN ALARM RELAYS (2-5) 1 to 4 1 F50 16
25A3 RTD #7 ALARM TEMPERATURE 1 to 250 1 °C F1 80
25A4 RTD #7 ALARM EVENTS 0 to 1 1 F105 0
25A5 RTD #7 TRIP 0 to 2 1 F115 0
25A6 RTD #7 TRIP VOTING 1 to 12 1 F122 7
25A7 ASSIGN TRIP RELAYS (1-4) 0 to 3 1 F50 1
25A8 RTD #7 TRIP TEMPERATURE 1 to 250 1 °C F1 90
25A9 RTD #7 NAME 0 to 8 1 F22 _
RTD TEMPERATURE / RTD #8
25E0 RTD #8 APPLICATION 0 to 4 1 F121 2
25E1 RTD #8 ALARM 0 to 2 1 F115 0
25E2 ASSIGN ALARM RELAYS (2-5) 1 to 4 1 F50 16
25E3 RTD #8 ALARM TEMPERATURE 1 to 250 1 °C F1 80
25E4 RTD #8 ALARM EVENTS 0 to 1 1 F105 0
25E5 RTD #8 TRIP 0 to 2 1 F115 0
25E6 RTD #8 TRIP VOTING 1 to 12 1 F122 8
25E7 ASSIGN TRIP RELAYS (1-4) 0 to 3 1 F50 1
25E8 RTD #8 TRIP TEMPERATURE 1 to 250 1 °C F1 90
25E9 RTD #8 NAME 0 to 8 1 F22 _
RTD TEMPERATURE / RTD #9
2620 RTD #9 APPLICATION 0 to 4 1 F121 2
2621 RTD #9 ALARM 0 to 2 1 F115 0
2622 ASSIGN ALARM RELAYS (2-5) 1 to 4 1 F50 16
2623 RTD #9 ALARM TEMPERATURE 1 to 250 1 °C F1 80
2624 RTD #9 ALARM EVENTS 0 to 1 1 F105 0
2625 RTD #9 TRIP 0 to 2 1 F115 0
2626 RTD #9 TRIP VOTING 1 to 12 1 F122 9
2627 ASSIGN TRIP RELAYS (1-4) 0 to 3 1 F50 1
2628 RTD #9 TRIP TEMPERATURE 1 to 250 1 °C F1 90
2629 RTD #9 NAME 0 to 8 1 F22 _
RTD TEMPERATURE / RTD #10
2660 RTD #10 APPLICATION 0 to 4 1 F121 2
2661 RTD #10 ALARM 0 to 2 1 F115 0
2662 ASSIGN ALARM RELAYS (2-5) 1 to 4 1 F50 16
2663 RTD #10 ALARM TEMPERATURE 1 to 250 1 °C F1 80
2664 RTD #10 ALARM EVENTS 0 to 1 1 F105 0
2665 RTD #10 TRIP 0 to 2 1 F115 0
2666 RTD #10 TRIP VOTING 1 to 12 1 F122 10
2667 ASSIGN TRIP RELAYS (1-4) 0 to 3 1 F50 1
2668 RTD #10 TRIP TEMPERATURE 1 to 250 1 °C F1 90
2669 RTD #10 NAME 0 to 8 1 F22 _
RTD TEMPERATURE / RTD #11
26A0 RTD #11 APPLICATION 0 to 4 1 F121 4
26A1 RTD #11 ALARM 0 to 2 1 F115 0
26A2 ASSIGN ALARM RELAYS (2-5) 1 to 4 1 F50 16
26A3 RTD #11 ALARM TEMPERATURE 1 to 250 1 °C F1 80
26A4 RTD #11 ALARM EVENTS 0 to 1 1 F105 0
Table 6–1: 489 MEMORY MAP (SHEET 17 OF 24)
ADDR NAME RANGE STEP UNITS FORMAT DEFAULT
1, 2, 3 See Table footnotes on page 6–33