S205 Skid-Steer Loader
89 Operation & Maintenance Manual
HYDRAULIC / HYDROSTATIC SYSTEM (CONT’D)
Removing And Replacing Hydraulic Fluid And Case
Drain Filters
See your SERVICE SCHEDULE for the service interval.
(See SERVICE SCHEDULE on Page 65.)
The fluid must be replaced if it becomes contaminated or
after major repairs. If the fluid is replaced, the hydrostatic
filter and both case drain filters must be replaced.
Figure 162
Raise the cab (See Raising on Page 71).
Open the rear door, remove the rear grill and remove the
reservoir fill cap (1) [Figure 162].
Remove the plug (2) [Figure 162] and use a pump to
remove the oil from the reservoir. Install the plug again.
Figure 163
Remove the motor access covers (Inset) [Figure 163]
from both sides of the loader.
Disconnect the fittings (1) [Figure 163] and remove the
case drain filter (2) [Figure 163]. Use a plug and cap to
prevent leakage.
Figure 164
Disconnect the fittings (1) [Figure 164] and remove the
case drain filter (2) [Figure 164]. Use a plug and cap to
prevent leakage.
Replace the hydraulic / hydrostatic filter element. (See
HYDRAULIC / HYDROSTATIC SYSTEM on Page 88.)
Replace both hydrostatic motor case drain filters (2)
[Figure 163] and [Figure 164].
Add the correct fluid to the reservoir until the fluid level is
at the center of the sight gauge (Do not overfill).
WARNING
Hydraulic fluid escaping under pressure can have
sufficient force to enter a person’s body by
penetrating the skin. This can cause serious injury
and possible death if proper medical treatment by a
physician familiar with this injury is not received
immediately.
W-2145-0290
Install the rear grill and close the rear door.
Lower the cab (See Lowering on Page 72).
P-54217
P-48011
1
2
2
1
P-54216
Left Side Shown
2
1
P-54215
Right Side Shown