6-58 Scanner Parameters
MX3-CE Reference Guide E-EQ-MX3CERG-A-ARC
Set Default Parameter
Use the Set Default parameter to reset all scanner parameters to their default values. See the “Pre-
Configured Default Settings” list in the Quick Start section earlier in this chapter.
Note: Scanning the Cancel barcode will not undo a Set Default scan.
Set All Defaults
Important
When all parameters are reset to the default values, you must again set the Laser On Time
parameter to 1.5 sec to match the default MX3-CE Max On Timer default value of 1.5 sec.
Time-out Between Same Symbol
Parameter Default Value: 1.0 Second
When in Continuous triggering mode, this parameter sets the minimum time that must elapse
before the scanner decodes a second barcode which is identical to one which has just been
decoded. This reduces the risk of accidentally scanning the same symbol twice. It is programmable
in 0.1 second increments from 0.0 to 9.9 seconds. There is no time-out when the value is set to 0.0
seconds.
To begin setting the time-out value between same symbols, scan this barcode:
Time-Out Between Same
S
Next, scan two numeric barcodes that correspond to the desired time using the “Keypad Number
Symbols” at the end of this chapter. Times less than 1.0 second must have a leading zero.
If you wish to change your selection, scan Cancel on the “Keypad Number Symbols” page.