Toro 5900 Lawn Mower User Manual


 
Groundsmaster 5900/5910Page 5 -- 34Electrical System
Maxi Fuses
Three (3) 60 amp maxi fuses are used on the Ground-
smaster for protection of main electrical circuits. The
maxifuseblockislocatedto the right of theoperatorseat
under the power center console (Fig. 59).
Identification and Function (Fig. 60)
Maxi Fuse #1 protects the controller power circuit.
Maxi Fuse #2 protects the main power circuit.
Maxi Fuse #3 protects the cab power circuit.
Testing
1. Make sure that ignition switch is OFF and key is re-
moved from switch.
2. Remove power center cover from operator platform
to access maxi fuses.
3. Remove fuse from fuse block for testing. Fuses
should have continuity across the terminals.
4. After fuse testing is completed, install and secure
power center cover.
1. Maxi fuse #1
2. Maxi fuse #2
3. Maxi fuse #3
Figure 59
1
2
3
Figure 60