Groundsmaster 4010--D Operator CabPage 9 -- 9
8. Labeland removehoses from condenser coil.Imme-
diately cap hoses and fittings to prevent moisture and
contaminants from entering the system.
9. Remove condenser coil from roof using Figure 6 as
a guide.
NOTE: Thereplacementof thedrier--receiver isrecom-
mended whenever the air conditioning system is
opened (see Heater/Evaporator in this section).
Installation (Fig. 5)
1. Install condenser coil to roof using Figure 6 as a
guide.
2. Remove caps that were placed on hoses and fittings
during the removal process. Using labels placed during
removal, properly secure hoses to condenser coil.
3. Position condenser cover and condenser fan to roof.
Secure cover and fan with removed fasteners (items 2,
6 and 8).
4. Secure condenser fan to condenser coil with button
head screws (item 10).
5. Connect wire harness connector to condenser fan
motor.
6. Make sure that all machine air conditioning c ompo-
nents are installed and secure.
7. Have a certified air conditioning service technician
evacuate the air conditioning system completely, prop-
erly recharge the system with R134a refrigerant and
then leak test the system. A/C system capacity is 1.35
pounds of R134a refrigerant.
8. Lower and secure roof assembly (see Roof Assem-
bly in this section).
1. Bushing (4 u sed)
2. Condenser coil
3. Fan shroud
4. Condenser fan
5. Isolator mount (4 used)
6. Coupler nut (4 used)
7. Screw (4 used)
8. Screw (4 used)
9. Screw (4 used)
10. Flat washer (4 used)
11. Clip (4 used)
12. Tray foam
13. Screen frame
14. End foam (2 used)
15. Screen
16. Side foam (2 used)
17. Lock nut
18. Latch plate
19. Friction washer (2 used)
20. Latch spacer
21. Carriage screw
Figure 6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
19
20
21
17
18
Operator
Cab