Fluke 105B Telescope User Manual


 
6 - 8 92B/96B/99B/105B Users Manual
Copying Waveforms or Settings
To copy a waveform or setting from one memory to
another, press to open the More Save window.
Figure 6-5. More Save Window
First choose what you want to copy, a waveform or a
setting. Then determine from which memory you want to
copy. On pressing (SELECT ITEM), you must
choose the memory to which you want to copy. The test
tool starts automatically with the next available memory.
Use this function to organize the sequence of your
waveforms or settings. This can be useful in semi-
automatic measurements.
RECALLING FROM MEMORY
You can review screens and recall waveforms and setups
from memory at any time.
Press to open the Recall from Memory menu.
CAUTION
A Master Reset destroys all memory contents and
leaves the initial setup with its default settings. Refer
to "Master Reset configuration" further on in this
chapter for a complete discussion of Initial Setup.
Recalling a Screen
You can display already saved screens with related setups.
This is presented as a picture that can no longer be
changed. Use this when you want to view a measurement
later.
1. Press (RECALL SCREEN) to view a saved
screen from screen memory (memory #).
At the same time the Recall Screen function key menu
is activated.
92B
Recall Menu