Command Descriptions
TDS 310, TDS 320 & TDS 350 Programmer Manual
2Ć47
CH<x>:POSition
Sets or queries the vertical position of the specified channel. The position
voltage value is applied to the signal before digitization. This is equivalent to
setting Position in the Vertical menu or adjusting the frontĆpanel VERTICAL
POSITION knob.
Vertical
CH<x>:OFFSet
CH<x>:POSition <NR3>
CH<x>:POSition?
POSition
CH
<x>
:
?
<Space> <NR3>
<NR3> is the desired position, in divisions from the center graticule. The
range is ±5 divisions.
CH2:POSITION 1.3E+00
positions the channel 2 input signal 1.3Ădivisions above the center of the
display.
CH1:POSITION?
might return –1.3E+00, indicating that the current position of channel 1
is at -1.3Ădivisions.
CH<x>:PRObe? (Query Only)
Returns the attenuation factor of the probe that is attached to the specified
channel.
Vertical
CH<x>:PRObe?
CH
<x> :
PRObe
?
<NR3>
CH2:PROBE?
might return 1.0E+1 for a 10x probe.